SEAGATE TECHNOLOGY, INC.
MAYNSTREAM 4000 INTERNAL
|
Device Type |
Internal Tape Drive |
|
Interface |
SCSI-2 |
|
Format |
DDS-DC |
|
Sustained Transfer Rate |
366 KBPS |
|
Size |
5.25 in. half height |
|
View |
Top |
|
USER CONFIGURABLE SETTINGS | |||
|
Setting |
Label |
Position | |
| » |
SCSI 2 mode enabled |
SW1/4 |
On |
|
SCSI 1 mode enabled |
SW1/4 |
Off | |
| » |
Parity check disabled |
SW1/5 |
Off |
|
Parity check enabled |
SW1/5 |
On | |
| » |
DDS pass through mode disabled |
SW1/6 |
Off |
|
DDS pass through mode enabled |
SW1/6 |
On | |
| » |
Factory configured - do not alter |
SW1/7 |
Reserved |
| » |
Self-Test disabled |
SW1/8 |
Off |
|
Self-Test enabled |
SW1/8 |
On | |
|
SCSI ADDRESS SELECTION | ||||
|
Address |
SW1/1 |
SW1/2 |
SW1/3 | |
| » |
0 |
Off |
Off |
Off |
|
1 |
On |
Off |
Off | |
|
2 |
Off |
On |
Off | |
|
3 |
On |
On |
Off | |
|
4 |
Off |
Off |
On | |
|
5 |
On |
Off |
On | |
|
6 |
Off |
On |
On | |
|
7 |
On |
On |
On | |
|
REMOTE SCSI ADDRESS SELECTION | ||||
|
Address |
JP1/1 |
JP1/2 |
JP1/3 | |
| » |
0 |
Off |
Off |
Off |
|
1 |
On |
Off |
Off | |
|
2 |
Off |
On |
Off | |
|
3 |
On |
On |
Off | |
|
4 |
Off |
Off |
On | |
|
5 |
On |
Off |
On | |
|
6 |
Off |
On |
On | |
|
7 |
On |
On |
On | |
|
Note: To use the remote SCSI address port, set SW1/1, SW1/2, and SW1/3 to the Off position. | ||||
|
TERMINATION POWER SELECTION | ||
|
Setting |
JP2 | |
| » |
TERMPWR disabled |
Open |
|
TERMPWR enabled |
Closed | |
|
MANUFACTURERS RECOMMENDED MEDIA | |
|
Tape |
Capacity |
|
90-meter DDS-DC DAT cartridge |
2.0GB |