TECHNOLOGY WORKS
ETHERNET SC
|
NIC Type |
Ethernet |
|
Transfer Rate |
10Mbps |
|
Data Bus |
SCSI |
|
Topology |
Linear Bus |
|
Wiring Type |
AUI Transceiver via DB-15 port RG-58A/U 50ohm coaxial |
|
Boot ROM |
Not available |
|
CONNECTIONS | |
|
Purpose |
Location |
|
SCSI connector |
S3 |
|
SCSI select switch |
S4 |
|
DC power connector |
S5 |
|
CABLE TYPE SELECTION | ||
|
Cable Type |
S1 |
S2 |
|
AUI Transceiver via DB-15 port |
Not installed |
Installed |
|
RG-58A/U 50ohm coaxial |
Installed |
Not installed |
|
DIAGNOSTIC LED(S) | ||
|
LED |
Status |
Condition |
|
LED1 |
On |
Thinnet is being used |
|
LED1 |
Off |
Thinnet is not being used |
|
LED2 |
On |
Data is being received |
|
LED2 |
Off |
Data is not being received |
|
LED3 |
On |
Data is being received |
|
LED3 |
Off |
Data is not being received |
|
LED4 |
On |
Data is being received |
|
LED4 |
Off |
Data is not being received |
|
LED5 |
On |
Data is being received |
|
LED5 |
Off |
Data is not being received |
|
LED6 |
On |
Data is being transmitted |
|
LED6 |
Off |
Data is not being transmitted |
|
LED7 |
On |
Data is being transmitted |
|
LED7 |
Off |
Data is not being transmitted |
|
LED8 |
On |
Data is being transmitted |
|
LED8 |
Off |
Data is not being transmitted |
|
LED9 |
On |
Data is being transmitted |
|
LED9 |
Off |
Data is not being transmitted |
|
LED10 |
On |
Thicknet is being used |
|
LED10 |
Off |
Thicknet is not being used |