TRENDWARE INTERNATIONAL, INC.
TE-32V
NIC Type: |
Ethernet |
Transfer Rate: |
10Mbps |
Data Bus: |
32-bit VESA-local bus |
Topology: |
Linear bus Star |
Wiring Type |
AUI transceiver via DB-15 port RG-58A/U 50ohm coaxial Shielded/Unshielded twisted pair |
Boot ROM |
Available |
WIRING TYPE |
|||
Setting |
JP1/jumper A |
JP1/jumper B |
|
» |
Unshielded twisted pair |
Closed |
Open |
|
AUI transceiver via DB-15 port |
Open |
Closed |
|
RG-58A/U 50ohm coaxial |
Closed |
Closed |
BOOT ROM |
||
Setting |
JP2/jumper A |
|
» |
Disabled |
Open |
|
Enabled |
Closed |
BOOT ROM ADDRESS |
|||
Address |
JP2/jumper B |
JP2/jumper C |
|
» |
D0000h |
Closed |
Open |
|
C0000h |
Open |
Open |
|
C8000h |
Open |
Closed |
|
D8000h |
Closed |
Closed |
INTERRUPT SELECT - JP3 |
|||||||||||
IRQ |
A |
B |
C |
D |
E |
F |
G |
H |
I |
J |
|
» |
IRQ5 |
Open |
Open |
Closed |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
|
IRQ3 |
Closed |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
|
IRQ4 |
Open |
Closed |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
|
IRQ6 |
Open |
Open |
Open |
Closed |
Open |
Open |
Open |
Open |
Open |
Open |
|
IRQ7 |
Open |
Open |
Open |
Open |
Closed |
Open |
Open |
Open |
Open |
Open |
|
IRQ9 |
Open |
Open |
Open |
Open |
Open |
Closed |
Open |
Open |
Open |
Open |
|
IRQ11 |
Open |
Open |
Open |
Open |
Open |
Open |
Closed |
Open |
Open |
Open |
|
IRQ12 |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Closed |
Open |
Open |
|
IRQ14 |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Closed |
Open |
|
IRQ15 |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Closed |
I/O ADDRESS |
|||
Address |
JP4/jumper A |
JP4/jumper B |
|
» |
300h |
Closed |
Closed |
|
320h |
Closed |
Open |
|
340h |
Open |
Closed |
|
360h |
Open |
Open |
VL-BUS SPEED |
||
Setting |
JP5 |
|
» |
Speed < 33 MHz |
Open |
|
Speed > 33MHz |
Closed |
DIAGNOSTIC LEDS |
||
LED |
Status |
Condition |
LED1 |
On |
Power on |
LED1 |
Blinking |
Data is being transmitted |
LED2 |
On |
Network connected successfully (UTP connection only) |
LED2 |
Blinking |
Data is being received |
LED3 |
On |
Network is not connected (RG-58A/U 50ohm coaxial connection only) |
LED3 |
Blinking |
Collision detected |
LED4 |
Blinking |
Transmission interrupted due to packet longer than allowable length (jabber) |