THOMAS-CONRAD CORPORATION
TC6242
|
NIC Type |
ARCnet |
|
Transfer Rate |
2.5Mbps |
|
Data Bus |
8-bit ISA |
|
Topology |
Star |
|
Wiring Type |
RG62A/U, 93ohm coaxial |
|
Boot ROM |
Available |
|
NODE ADDRESS | ||||||||
|
Node |
SW2/ 1 |
SW2/ 2 |
SW2/ 3 |
SW2/ 4 |
SW2/ 5 |
SW2/ 6 |
SW2/ 7 |
SW2/ 8 |
|
0 |
- |
- |
- |
- |
- |
- |
- |
- |
|
1 |
Off |
On |
On |
On |
On |
On |
On |
On |
|
2 |
On |
Off |
On |
On |
On |
On |
On |
On |
|
3 |
Off |
Off |
On |
On |
On |
On |
On |
On |
|
4 |
On |
On |
Off |
On |
On |
On |
On |
On |
|
251 |
Off |
Off |
On |
Off |
Off |
Off |
Off |
Off |
|
252 |
On |
On |
Off |
Off |
Off |
Off |
Off |
Off |
|
253 |
Off |
On |
Off |
Off |
Off |
Off |
Off |
Off |
|
254 |
On |
Off |
Off |
Off |
Off |
Off |
Off |
Off |
|
255 |
Off |
Off |
Off |
Off |
Off |
Off |
Off |
Off |
|
Note:Node address 0 is used for messaging between nodes and must not be used. A total of 255 node address settings are available. The switches are a binary representation of the decimal node addresses. Switch 1 is the Least Significant Bit and switch 8 is the Most Significant Bit. The switches have the following decimal values: switch 1=1, 2=2, 3=4, 4=8, 5=16, 6=32, 7=64, 8=128. Turn off the switches and add the values of the off switches to obtain the correct node address. (On=0, off=1) | ||||||||
|
INTERRUPT REQUEST | ||||||
|
IRQ |
JP1 |
JP2 |
JP3 |
JP4 |
JP5 | |
| » |
2 |
Open |
Open |
Open |
Open |
Closed |
|
3 |
Closed |
Open |
Open |
Open |
Open | |
|
4 |
Open |
Closed |
Open |
Open |
Open | |
|
5 |
Open |
Open |
Closed |
Open |
Open | |
|
7 |
Open |
Open |
Open |
Closed |
Open | |
|
CABLE LENGTH | |||
|
Length |
JP6 |
JP7 | |
| » |
Under 20,000 feet |
Open |
Open |
|
Greater than 20,000 feet |
Closed |
Closed | |
|
Note: All NICs on the network must have this opition set the same. | |||
|
BASE MEMORY ADDRESS | |||||||
|
Address |
SW1/ 1 |
SW1/ 2 |
SW1/ 3 |
SW1/ 4 |
SW1/ 5 |
SW1/ 6 | |
| » |
D000h |
Off |
Off |
On |
Off |
On |
On |
|
C000h |
Off |
Off |
On |
On |
On |
On | |
|
C400h |
Off |
Off |
On |
On |
On |
Off | |
|
C800h |
Off |
Off |
On |
On |
Off |
On | |
|
CC00h |
Off |
Off |
On |
On |
Off |
Off | |
|
D400h |
Off |
Off |
On |
Off |
On |
Off | |
|
D800h |
Off |
Off |
On |
Off |
Off |
On | |
|
DC00h |
Off |
Off |
On |
Off |
Off |
Off | |
|
COMPATABILITY MODE | ||
|
Setting |
SW1/ 8 | |
| » |
Enhanced mode |
On |
|
Compatible mode |
Off | |
|
Note: Enhanced mode optimizes performance and minimizes conflicts of your hardware by using a Thomas-Conrad
| ||
|
I/O BASE ADDRESS | |||||||
|
Address |
SW3/ 3 |
SW3/ 4 |
SW3/ 5 |
SW3/ 6 |
SW3/ 7 |
SW3/ 8 | |
| » |
2E0h |
Off |
On |
Off |
Off |
Off |
On |
|
2F0h |
Off |
On |
Off |
Off |
Off |
Off | |
|
300h |
Off |
Off |
On |
On |
On |
On | |
|
310h |
Off |
Off |
On |
On |
On |
Off | |
|
320h |
Off |
Off |
On |
On |
Off |
On | |
|
330h |
Off |
Off |
On |
On |
Off |
Off | |
|
340h |
Off |
Off |
On |
Off |
On |
On | |
|
350h |
Off |
Off |
On |
Off |
On |
Off | |
|
360h |
Off |
Off |
On |
Off |
Off |
On | |
|
370h |
Off |
Off |
On |
Off |
Off |
Off | |
|
380h |
Off |
Off |
Off |
On |
On |
On | |
|
390h |
Off |
Off |
Off |
On |
On |
Off | |
|
3A0h |
Off |
Off |
Off |
On |
Off |
On | |
|
3B0h |
Off |
Off |
Off |
On |
Off |
Off | |
|
3C0h |
Off |
Off |
Off |
Off |
On |
On | |
|
3D0h |
Off |
Off |
Off |
Off |
On |
Off | |
|
3E0h |
Off |
Off |
Off |
Off |
Off |
On | |
|
3F0h |
Off |
Off |
Off |
Off |
Off |
Off | |
|
Note: SW3/ 1 & SW3/ 2 are always in the on position. | |||||||
|
DIAGNOSTIC LED(S) | ||
|
LED |
Status |
Condition |
|
LED1 |
On |
Data is being transmitted/received. |
|
LED1 |
Off |
Data is not being transmitted/received. |