RACAL-INTERLAN, INC.
NP600A
|
NIC Type |
Ethernet |
|
Transfer Rate |
10Mbps |
|
Data Bus |
16-bit ISA |
|
Topology |
Linear Bus |
|
Wiring Type |
AUI Transceiver via DB-15 port RG-58A/U 50ohm coaxial |
|
Boot ROM |
Not available |
|
I/O BASE ADDRESS JUMPER SETTINGS | |||||||
|
Address |
A3 |
A4 |
A5 |
A6 |
A7 |
A8 |
A9 |
|
200h |
1 & 2 |
1 & 2 |
1 & 2 |
1 & 2 |
1 & 2 |
1 & 2 |
2 & 3 |
|
208h |
2 & 3 |
1 & 2 |
1 & 2 |
1 & 2 |
1 & 2 |
1 & 2 |
2 & 3 |
|
210h |
1 & 2 |
2 & 3 |
1 & 2 |
1 & 2 |
1 & 2 |
1 & 2 |
2 & 3 |
|
218h |
2 & 3 |
2 & 3 |
1 & 2 |
1 & 2 |
1 & 2 |
1 & 2 |
2 & 3 |
|
220h |
1 & 2 |
1 & 2 |
2 & 3 |
1 & 2 |
1 & 2 |
1 & 2 |
2 & 3 |
|
3D8h |
2 & 3 |
2 & 3 |
1 & 2 |
2 & 3 |
2 & 3 |
2 & 3 |
2 & 3 |
|
3E0h |
1 & 2 |
1 & 2 |
2 & 3 |
2 & 3 |
2 & 3 |
2 & 3 |
2 & 3 |
|
3E8h |
2 & 3 |
1 & 2 |
2 & 3 |
2 & 3 |
2 & 3 |
2 & 3 |
2 & 3 |
|
3F0h |
1 & 2 |
2 & 3 |
2 & 3 |
2 & 3 |
2 & 3 |
2 & 3 |
2 & 3 |
|
3F8h |
2 & 3 |
2 & 3 |
2 & 3 |
2 & 3 |
2 & 3 |
2 & 3 |
2 & 3 |
|
Note: A total of 127 memory base address settings are available. The switches are a binary representation of the hexadecimal addresses. Jumper A3 is the Least Significant Bit and Jumper A9 is the Most Significant Bit. The jumpers have the following decimal values: Jumper A3=8, A4=16, A5=32, A6=64, A7=16, A8=256, A9=512. Add the values of the jumpers with pins 2 & 3 closed to obtain the correct memory address. (On=pins 2 & 3 closed, Off=pins 1 & 2 closed) | |||||||
|
CABLE TYPE SELECTION | |
|
Cable Type |
NTS |
|
AUI Transceiver via DB-15 port |
Configuration 1 |
|
RG-58A/U 50ohm coaxial |
Configuration 2 |
|
INTERRUPT SELECTION | |||||
|
IRQ |
JP1 |
JP2 |
JP3 |
JP4 |
JP5 |
|
3 |
Closed |
Open |
Open |
Open |
Open |
|
5 |
Open |
Closed |
Open |
Open |
Open |
|
9 |
Open |
Open |
Closed |
Open |
Open |
|
11 |
Open |
Open |
Open |
Closed |
Open |
|
15 |
Open |
Open |
Open |
Open |
Closed |
|
DMA CHANNEL SELECTION | ||||
|
Channel |
CH7 |
CH5 |
CH1 |
CH3 |
|
DMA7 |
Closed |
Open |
Open |
Open |
|
DMA5 |
Open |
Closed |
Open |
Open |
|
DMA1 |
Open |
Open |
Closed |
Open |
|
DMA3 |
Open |
Open |
Open |
Closed |
|
DIAGNOSTIC LED(S) | ||
|
LED1 (Red) |
LED2 (Green) |
Condition |
|
Off |
On |
Network connection is good |
|
On |
On |
Kernal and hardware failure |
|
On |
Off |
Hardware failure |
|
Off |
Off |
network connection is broken |
|
Note: LED3 is lit only when UTP network connection is good | ||
|
FACTORY CONFIGURED SETTINGS | |
|
Jumper |
Setting |
|
W15-18 |
Pins 2 & 3 closed |