PURE DATA, LTD.
PDI7023-16FL
NIC Type |
Ethernet |
Transfer Rate |
10Mbps |
Data Bus |
16-bit ISA |
Topology |
Star |
Wiring Type |
62.5/125 m m Fiber optic cable (e.g. Belden 227412) |
Boot ROM |
Not available |
INTERRUPT REQUEST |
|||||||||||
IRQ |
E2A |
E2B |
E2C |
E2D |
E2E |
E2F |
E2G |
E2H |
E2I |
E2J |
|
|
2/9 |
Open |
Open |
Open |
Open |
Closed |
Open |
Open |
Open |
Open |
Open |
|
3 |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Closed |
» |
4 |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Closed |
Open |
|
5 |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Closed |
Open |
Open |
|
6 |
Open |
Open |
Open |
Open |
Open |
Open |
Closed |
Open |
Open |
Open |
|
7 |
Open |
Open |
Open |
Open |
Open |
Closed |
Open |
Open |
Open |
Open |
|
10 |
Open |
Open |
Open |
Closed |
Open |
Open |
Open |
Open |
Open |
Open |
|
11 |
Open |
Open |
Closed |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
|
12 |
Open |
Closed |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
|
15 |
Closed |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
LOOP BACK ENABLE |
||
Setting |
E7 |
|
» |
Disabled |
Pins 1 & 2 closed |
|
Enabled |
Pins 2 & 3 closed |
Note:The loop back is used with diagnostic software to trouble-shoot the card. |
I/O BASE ADDRESS |
||||
Address |
SW1/1 |
SW1/2 |
SW1/3 |
|
|
260h |
On |
On |
On |
|
290h |
Off |
On |
On |
|
2E0h |
On |
Off |
On |
|
2F0h |
Off |
Off |
On |
» |
300h |
On |
On |
Off |
|
350h |
Off |
On |
Off |
|
380h |
On |
Off |
Off |
|
3E0h |
Off |
Off |
Off |
JUMPER E6 ENABLE |
||
Setting |
SW1/5 |
|
» |
Enabled |
On |
|
Disabled |
Off |
Note:If this option is disabled (SW1/5 Off) the options selected using E6 are disabled. |
EXTENDED TRANSMIT TIMEOUT AND SIGNAL QUALITY ERROR (SQE) TEST |
||||
Timeout |
SQE |
E6A |
E6B |
E6C |
Enabled |
Enabled |
Closed |
Open |
Open |
Disabled |
Disabled |
Open |
Closed |
Open |
Enabled |
Disabled |
Open |
Open |
Closed |
Note:SW1/5 must be set to on for these settings to be valid. With extended transmit timeout enabled, if the card is transmitting for an extented amount of time the transmission will be interrupted and continued after a preset time. This keeps the card from dominating the network. Signal Quality Error (SQE) is a test of the collision circuitry and path. E6A, E6B, and E6C are located on the PIM module. |
LINK INTEGRITY TEST |
||
Setting |
SW1/7 |
|
» |
Enabled |
On |
|
Disabled |
Off |
Note:E7 is located on the PIM module. |
FACTORY CONFIGURED SETTINGS |
|
Switch |
Setting |
SW1/4 |
Off |
SW1/6 |
On |
SW1/8 |
Off |
DIAGNOSTIC LED(S) |
|||
LED |
Color |
Status |
Condition |
LED1 |
Green |
On |
Data is being transmitted |
LED1 |
Green |
Off |
Data is not being transmitted |
LED2 |
Amber |
On |
Data is being received |
LED2 |
Amber |
Off |
Data is not being received |
LED3 |
Amber |
On |
Network connection is good |
LED3 |
Amber |
Off |
Network connection is broken |
LED4 |
Red |
On |
Card is transmitting for an extended time |
LED4 |
Red |
Off |
Normal operation |
LED5 |
Red |
On |
Collision detected on network |
LED5 |
Red |
Off |
Normal operation |