GARRETT COMMUNICATIONS
MAGNUM 120
|
Card Type |
Ethernet Transceiver |
|
NIC Type |
Ethernet |
|
Maximum Onboard Memory |
Unidentified |
|
Boot ROM |
Not available |
|
Network Transfer Rate |
10Mbps |
|
Topology |
Linear Bus |
|
Wiring Type |
AUI transceiver via DB-15 port (2), RG-58A/U 50ohm coaxial |
|
Data Bus |
External |
|
CONNECTIONS | |||
|
Function |
Label |
Function |
Label |
|
BNC-T network tap connector |
CN1 |
AUI connector |
CN3 |
|
AUI connector |
CN2 | ||
|
USER CONFIGURABLE SETTINGS | |||
|
Function |
Label |
Position | |
|
SQE on with LED indication |
J1 |
Pins 1 & 2 closed | |
|
SQE on without LED indication |
J1 |
Open | |
| » |
SQE off |
J1 |
Pins 2 & 3 closed |
|
DIAGNOSTIC LED(S) | |||
|
LED |
Color |
Status |
Condition |
|
LED1 |
Green |
On |
Data is being transmitted (port 2) |
|
LED1 |
Green |
Off |
Data is not being transmitted (port 2) |
|
LED2 |
Green |
On |
Data is being transmitted (port 3) |
|
LED2 |
Green |
Off |
Data is not being transmitted (port 3) |
|
LED3 |
Green |
On |
Data is being received |
|
LED3 |
Green |
Off |
Data is not being received |
|
LED4 |
Yellow |
On |
Collision detected on network |
|
LED4 |
Yellow |
Off |
Collision not detected on network |
|
LED5 |
Yellow |
On |
SQE enabled |
|
LED5 |
Yellow |
Off |
SQE disabled |