EAGLE TECHNOLOGY
NE2000T
NIC Type |
Ethernet |
Transfer Rate |
10Mbps |
Data Bus |
16-bit ISA |
Topology |
Linear Bus/Star |
Wiring Type |
Unshielded twisted pair |
Boot ROM |
Available |
BOOT ROM | ||
Setting |
W11 | |
» |
Disabled |
Open |
Enabled |
Closed |
COMPATIBILITY MODE | ||
Setting |
W16 | |
» |
Normal ISA bus timing |
Closed |
Alternate ISA bus timing |
Open | |
Note:Alternate ISA bus timing is used if the host computer is not 100% ISA bus compatible (such as the Compaq 286, IBM PC 30-286 or systems that use the C & T chip set. |
I/O BASE ADDRESS | |||
Address |
W9 |
W10 | |
» |
300h |
Closed |
Closed |
320h |
Open |
Closed | |
340h |
Closed |
Open | |
360h |
Open |
Open |
INTERRUPT REQUEST | |||||
IRQ |
W12 |
W13 |
W14 |
W15 | |
» |
3 |
Open |
Closed |
Open |
Open |
2 |
Closed |
Open |
Open |
Open | |
4 |
Open |
Open |
Closed |
Open | |
5 |
Open |
Open |
Open |
Closed |
TOPOLOGY TYPE SELECT | ||
Type |
W1 | |
» |
Linear Bus |
Open |
Star |
Closed |
DIAGNOSTIC LED(S) | |||
LED |
Color |
Status |
Condition |
LED1 |
Green |
Off |
Network connection is good |
LED1 |
Green |
On |
Network connection is broken |
LED2 |
Red |
On |
Polarity is correct |
LED2 |
Red |
Off |
Polarity is reversed |