EDIMAX COMPUTER COMPANY
EN-6360 (Version 1.1)
NIC Type |
Ethernet |
Transfer Rate |
10Mbps |
Data Bus |
16-bit ISA |
Topology |
Star |
Wiring Type |
Unshielded twisted pair AUI transceiver via DB-15 port |
Boot ROM |
Available |
COMPATIBILITY MODE | ||
Setting |
JP6 | |
» |
DIsabled |
Pins 1 & 2 closed |
Enabled |
Pins 2 & 3 closed | |
Note: On some systems the data bus timing is not truly IBM PC/AT compatible. If the card is not initializing, enabling the compatibility mode may allow the card to function properly |
BOOT ROM ADDRESS | |||||
Address |
JP7A |
JP7B |
JP7C |
JP7D | |
C0000h |
Closed |
Closed |
Closed |
Closed | |
C4000h |
Open |
Closed |
Closed |
Closed | |
» |
C8000h |
Closed |
Open |
Closed |
Closed |
CC000h |
Open |
Open |
Closed |
Closed | |
D0000h |
Closed |
Closed |
Open |
Closed | |
D4000h |
Open |
Closed |
Open |
Closed | |
D8000h |
Closed |
Open |
Open |
Closed | |
DC000h |
Open |
Open |
Open |
Closed |
BOOT ROM | ||
Setting |
JP8 | |
» |
Disabled |
Open |
Enabled |
Closed |
CABLE TYPE | |||
Type |
JP10A-JP10F |
JP11 | |
» |
Unshielded twisted pair |
Pins 1 & 2 closed |
Pins 2 & 3 closed |
AUI transceiver via DB-15 port |
Pins 2 & 3 closed |
Pins 1 & 2 closed |
I/O BASE ADDRESS | |||
Address |
JP12A |
JP12B | |
» |
300h |
Closed |
Closed |
320h |
Open |
Closed | |
340h |
Closed |
Open | |
360h |
Open |
Open |
INTERRUPT SETTINGS | |||||
IRQ |
JP12C |
JP12D |
JP12E |
JP12F | |
2 |
Closed |
Open |
Open |
Open | |
» |
3 |
Open |
Closed |
Open |
Open |
4 |
Open |
Open |
Closed |
Open | |
5 |
Open |
Open |
Open |
Closed |
DIAGNOSTIC LED(S) | |||
LED |
Color |
Status |
Condition |
LED1 |
Green |
On |
Data is being transmitted |
LED1 |
Green |
Off |
Data is not being transmitted |
LED2 |
Green |
On |
Data is being received |
LED2 |
Green |
Off |
Data is not being received |
LED3 |
Red |
On |
Twisted pair connection is good |
LED3 |
Red |
Off |
Twisted pair connection is broken |