COMPU-SHACK PRODUCTION, GMBH
CS-ARCNET-KARTE TURBO, CS-ARCNET-KARTE SPECIAL
|
NIC Type: |
ARCnet |
|
Transfer Rate: |
2.5Mbps |
|
Data Bus: |
8-bit ISA |
|
Topology: |
Linear Bus |
|
Wiring Type |
RG62A/U 93ohm coaxial |
|
Boot ROM |
Available |
|
INTERRUPT SELECT - J2 | ||||||
|
IRQ |
Jumper A |
Jumper B |
Jumper D |
Jumper D |
Jumper E | |
| » |
IRQ2 |
Closed |
Open |
Open |
Open |
Open |
|
IRQ3 |
Open |
Closed |
Open |
Open |
Open | |
|
IRQ4 |
Open |
Open |
Closed |
Open |
Open | |
|
IRQ5 |
Open |
Open |
Open |
Closed |
Open | |
|
IRQ7 |
Open |
Open |
Open |
Open |
Closed | |
|
RESPONSE TIME-OUTS | |||
|
Response Time |
J4/jumper A |
J4/jumper B | |
| » |
74.7µs |
Open |
Open |
|
283.4µs |
Closed |
Open | |
|
561.8µs |
Open |
Closed | |
|
1118.6µs |
Closed |
Closed | |
|
BOOT ROM | ||
|
Setting |
S1/1 | |
| » |
Disabled |
Off |
|
Enabled |
On | |
|
I/O ADDRESS | |||||||
|
Address |
S1/1 |
S1/2 |
S1/3 |
S1/4 |
S1/5 |
S1/6 | |
| » |
2E0h |
Off |
On |
Off |
Off |
Off |
On |
|
200h |
Off |
On |
On |
On |
On |
On | |
|
210h |
Off |
On |
On |
On |
On |
Off | |
|
220h |
Off |
On |
On |
On |
Off |
On | |
|
230h |
Off |
On |
On |
On |
Off |
Off | |
|
240h |
Off |
On |
On |
Off |
On |
On | |
|
250h |
Off |
On |
On |
Off |
On |
Off | |
|
260h |
Off |
On |
On |
Off |
Off |
On | |
|
270h |
Off |
On |
On |
Off |
Off |
Off | |
|
280h |
Off |
On |
Off |
On |
On |
On | |
|
290h |
Off |
On |
Off |
On |
On |
Off | |
|
2A0h |
Off |
On |
Off |
On |
Off |
On | |
|
2B0h |
Off |
On |
Off |
On |
Off |
Off | |
|
2C0h |
Off |
On |
Off |
Off |
On |
On | |
|
2D0h |
Off |
On |
Off |
Off |
On |
Off | |
|
2F0h |
Off |
On |
Off |
Off |
Off |
Off | |
|
300h |
Off |
Off |
On |
On |
On |
On | |
|
310h |
Off |
Off |
On |
On |
On |
Off | |
|
320h |
Off |
Off |
On |
On |
Off |
On | |
|
330h |
Off |
Off |
On |
On |
Off |
Off | |
|
340h |
Off |
Off |
On |
Off |
On |
On | |
|
350h |
Off |
Off |
On |
Off |
On |
Off | |
|
360h |
Off |
Off |
On |
Off |
Off |
On | |
|
370h |
Off |
Off |
On |
Off |
Off |
Off | |
|
380h |
Off |
Off |
Off |
On |
On |
On | |
|
390h |
Off |
Off |
Off |
On |
On |
Off | |
|
3A0h |
Off |
Off |
Off |
On |
Off |
On | |
|
3B0h |
Off |
Off |
Off |
On |
Off |
Off | |
|
3C0h |
Off |
Off |
Off |
Off |
On |
On | |
|
3D0h |
Off |
Off |
Off |
Off |
On |
Off | |
|
3E0h |
Off |
Off |
Off |
Off |
Off |
On | |
|
3F0h |
Off |
Off |
Off |
Off |
Off |
Off | |
|
MEMORY ADDRESS | |||||
|
Address |
S1/7 |
S1/8 |
S1/9 |
S1/10 | |
| » |
D0000h |
On |
Off |
On |
On |
|
C0000h |
On |
On |
On |
On | |
|
C4000h |
On |
On |
On |
Off | |
|
C8000h |
On |
On |
Off |
On | |
|
CC000h |
On |
On |
Off |
Off | |
|
D4000h |
On |
Off |
On |
Off | |
|
D8000h |
On |
Off |
Off |
On | |
|
DC000h |
On |
Off |
Off |
Off | |
|
E0000h |
Off |
On |
On |
On | |
|
E4000h |
Off |
On |
On |
Off | |
|
E8000h |
Off |
On |
Off |
On | |
|
EC000h |
Off |
On |
Off |
Off | |
|
F0000h |
Off |
Off |
On |
On | |
|
F4000h |
Off |
Off |
On |
Off | |
|
F8000h |
Off |
Off |
Off |
On | |
|
FC000h |
Off |
Off |
Off |
Off | |
|
NODE ID NUMBER | ||||||||
|
ID # |
S2/1 |
S2/2 |
S2/3 |
S2/4 |
S2/5 |
S2/6 |
S2/7 |
S2/8 |
|
1 |
On |
Off |
Off |
Off |
Off |
Off |
Off |
Off |
|
255 |
On |
On |
On |
On |
On |
On |
On |
On |
|
Note:Nodes can be numbered from 1 to 255. The switches are a binary representation of the node numbers. When a switch is on, the corresponding bit is set to 1 and has the following decimal value: S2/1=1, S2/2=2, S2/3=4, S2/4=8, S2/5=16, S2/6=32, S2/7=64, S2/8=128. | ||||||||
|
DIAGNOSTIC LED | |
|
Status |
Condition |
|
On |
Data is being transmitted or received |
|
Off |
Data is not being transmitted or received |