CABLETRON SYSTEMS, INC.
E6030/-X, E6040/-X (Fiber Optic)
|
NIC Type |
Ethernet |
|
Transfer Rate |
10Mbps |
|
Data Bus |
32-bit NuBus (Apple) |
|
Topology |
Star |
|
Wiring Type |
200µ fiber optic cable AUI transceiver via DB-15 port |
|
Boot ROM |
Not Available |

|
CONNECTIONS |
|
|
Purpose |
Location |
|
SMA 905 Receive Connector (gray) |
CN1 |
|
SMA 905 Transmit Connector (black) |
CN2 |
|
SIGNAL QUALITY |
||
|
Setting |
JP2 |
|
|
» |
SQE test disabled |
Pins 2 & 3 Closed |
|
|
SQE test enabled |
Pins 1 & 2 Closed |
|
Note:Signal Quality Error (SQE) is an internal test of the collision circuit and path. |
||
|
CABLE TYPE |
||
|
Type |
Switch PSS |
|
|
» |
200µ fiber optic cable |
Off |
|
|
AUI transceiver via DB-15 port |
On |

|
DIAGNOSTIC LED(S) |
|||
|
LED |
Color |
Status |
Condition |
|
1 |
Green |
On/Blinking |
Data is being transmitted |
|
1 |
Green |
Off |
Data is not being transmitted |
|
2 |
Red |
On/Blinking |
Collision detected on network |
|
2 |
Red |
Off |
Normal operation |
|
3 |
Yellow |
On/Blinking |
Data is being received |
|
3 |
Yellow |
Off |
Data is not being received |
|
4 |
Green |
On |
Fiber optic network connection is good |
|
4 |
Green |
Off |
Fiber optic network connection is broken |