CNET TECHNOLOGY, INC.
CN600E/680E
NIC Type |
Ethernet |
Transfer Rate |
10Mbps |
Data Bus |
16-bit ISA |
Topology |
Star |
Wiring Type |
Unshielded wisted pair AUI transceiver via DB-15 port |
Boot ROM |
Available |
BOOT ROM | ||
Setting |
JP1 | |
» |
Disabled |
Pins 1 & 2 Closed |
Enabled |
Pins 2 & 3 Closed |
WAIT STATE | ||
Setting |
JP2 | |
» |
0 wait states |
pins 1 & 2 closed |
1 wait state |
pins 2 & 3 closed |
INTERRUPT REQUEST | |||||||||||
IRQ |
JP3A |
JP3B |
JP3C |
JP3D |
JP3E |
JP3F |
JP3G |
JP3H |
JP3I |
JP3J | |
2/9 |
Closed |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Open | |
» |
3 |
Open |
Closed |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
4 |
Open |
Open |
Closed |
Open |
Open |
Open |
Open |
Open |
Open |
Open | |
5 |
Open |
Open |
Open |
Closed |
Open |
Open |
Open |
Open |
Open |
Open | |
7 |
Open |
Open |
Open |
Open |
Closed |
Open |
Open |
Open |
Open |
Open | |
10 |
Open |
Open |
Open |
Open |
Open |
Closed |
Open |
Open |
Open |
Open | |
11 |
Open |
Open |
Open |
Open |
Open |
Open |
Closed |
Open |
Open |
Open | |
12 |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Closed |
Open |
Open | |
14 |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Closed |
Open | |
15 |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Closed |
CABLE TYPE | ||
Type |
JP16 | |
» |
Unshielded twisted pair |
Pins 2 & 3 Closed |
AUI transceiver via DB-15 |
Pins 1 & 2 Closed |
LINK INTEGRITY TEST | ||
Setting |
JP31 | |
» |
Enabled |
Pins 1 & 2 Closed |
Disabled |
Pins 2 & 3 Closed | |
Note:Link Integrity is only used with 10Base-T wiring. When using an AUI transciever, the test should be disabled. |
BOOT ROM ADDRESS | |||||
Address |
SW1/1 |
SW1/2 |
SW1/3 |
SW1/4 | |
C0000h |
On |
On |
On |
On | |
C4000h |
On |
On |
On |
Off | |
» |
C8000h |
On |
On |
Off |
On |
CC000h |
On |
On |
Off |
Off | |
D0000h |
On |
Off |
On |
On | |
D4000h |
On |
Off |
On |
Off | |
D8000h |
On |
Off |
Off |
On | |
DC000h |
On |
Off |
Off |
Off |
I/O BASE ADDRESS | |||||
Address |
SW1/5 |
SW1/6 |
SW1/7 |
SW1/8 | |
200-2IFh |
On |
On |
On |
On | |
220-23Fh |
On |
On |
On |
Off | |
240-25Fh |
On |
On |
Off |
On | |
280-29Fh |
On |
Off |
On |
On | |
2A0-2BFh |
On |
Off |
On |
Off | |
2C0-2DFh |
On |
Off |
Off |
On | |
» |
300-31Fh |
Off |
On |
On |
On |
320-33Fh |
Off |
On |
On |
Off | |
340-35Fh |
Off |
On |
Off |
On | |
360-37Fh |
Off |
On |
Off |
Off |
DIAGNOSTIC LED(S) | |||
LED |
Color |
Status |
Condition |
LED1 |
Red |
Blinking |
Data is being received |
LED1 |
Red |
Off |
Data is not being received |
LED2 |
Green |
On |
Data is being transmitted |
LED2 |
Green |
Off |
Data is not being transmitted |