RESEARCH IN MOTION LIMITED
MX25
Card Type |
X.25 PAD |
Chip Set |
Unidentified |
I/O Options |
Printer/diagnostic port |
Transfer Rate |
19.2Kbps |
Data Bus |
External |
CONNECTIONS | |||
Function |
Label |
Function |
Label |
RS-232 X.25 to DTE |
CN1 |
Diagnostic/printer port |
CN3 |
RS-232 to X.25 network transmission device |
CN2 |
DC power |
CN4 |
USER CONFIGURABLE SETTINGS | |||
Setting |
Label |
Position | |
» |
Hardware flow control is not being used |
J401 |
Open |
Hardware flow control is being used |
J401 |
Closed | |
» |
Factory configured - do not alter |
J201 |
Open |
» |
Factory configured - do not alter |
J402 |
Open |
» |
Factory configured - do not alter |
J403 |
Open |
» |
Factory configured - do not alter |
J404 |
Open |
DIAGNOSTIC LED(S) | |||
LED |
Color |
Status |
Condition |
ERR |
Red |
On |
A fatal error has occurred (after initial start-up) |
ERR |
Red |
Off |
A fatal error has not occurred |
RX1 |
Red |
On |
PAD is receiving data from DTE |
RX1 |
Red |
Off |
PAD is not receiving data from DTE |
TX1 |
Red |
On |
PAD is transmitting data to DTE |
TX1 |
Red |
Off |
PAD is not transmitting data to DTE |
HP |
Red |
On |
PAD is waiting for an incoming call |
HP |
Red |
Off |
PAD is busy and not waiting for an incoming call |
COMP |
Red |
On |
X.25 link to network is good |
COMP |
Red |
Off |
X.25 link to network is not good |
RX2 |
Red |
On |
PAD is receiving data from network |
RX2 |
Red |
Off |
PAD is not receiving data from network |
TX2 |
Red |
On |
PAD is transmitting data to network |
TX2 |
Red |
Off |
PAD is not transmitting data to network |
CONT |
Red |
On |
X.25 call has connected |
CONT |
Red |
Off |
No X.25 call has connected |
PWR |
Red |
On |
Power is on |
PWR |
Red |
Off |
Power is off |
Note:LEDs will blink during self-test sequence. |