COMTROL CORPORATION
HOSTESS CLUSTER
|
Category |
Serial controller |
|
Chipset Controller |
NEC |
|
I /O Options Supported |
Serial ports (16) |
|
Maximum Onboard Memory |
2MB |

|
CONNECTIONS |
|||
|
Purpose |
Location |
Purpose |
Location |
|
100-pin serial interface connector |
CN1 |
8-port upgrade card connector |
CN3 |
|
8-port upgrade card connector |
CN2 |
|
|
|
RS-232/RS-422 SELECT - JP1-JP8 |
|||||
|
Setting |
Jumper A |
Jumper B |
Jumper C |
Jumper D |
|
|
» |
RS-232 |
Pins 1 & 2 closed |
Pins 1 & 2 closed |
Pins 1 & 2 closed |
Pins 1 & 2 closed |
|
|
RS-422 |
Pins 2 & 3 closed |
Pins 2 & 3 closed |
Pins 2 & 3 closed |
Pins 2 & 3 closed |
|
Note:JP1-JP8 correspond to serial ports 1 - 8, respectively. Jumper D does not exist on JP5-JP8. |
|||||
|
PORT 1 FULL/HALF DUPLEX SELECT |
|
|
Setting |
FD1 |
|
Half-duplex mode |
Pins 1 & 2 closed |
|
Full-duplex mode (DMA1) |
Pins 2 & 3 closed |
|
PORT 2 FULL/HALF DUPLEX SELECT |
|
|
Setting |
FD2 |
|
Half-duplex mode |
Pins 1 & 2 closed |
|
Full-duplex mode (DMA2) |
Pins 2 & 3 closed |
|
PORTS 1 & 2 RS-232 SYNCHRONOUS/ASYNCHRONOUS SELECT - JP9 |
||
|
Setting |
Jumper A - Jumper E |
Jumper F - Jumper M |
|
Asynchronous |
Pins 1 & 2 closed |
Pins 1 & 2 closed |
|
Synchronous |
Pins 2 & 3 closed |
Pins 1 & 2 closed |
|
PORT 1 DATA TERMINAL READY (DTR) OPTIONS |
|||
|
Setting |
JP14 |
JP15 |
|
|
» |
Normal RS-232 |
Closed |
Open |
|
|
Synchronous RS-232 |
Open |
Closed |
|
PORT 2 DATA TERMINAL READY (DTR) OPTIONS |
|||
|
Setting |
JP16 |
JP17 |
|
|
» |
Normal RS-232 |
Closed |
Open |
|
|
Synchronous RS-232 |
Open |
Closed |
|
I/O ADDRESS |
||||
|
Setting |
SW1/1 |
SW1/2 |
SW1/3 |
|
|
» |
218h |
Off |
Off |
Off |
|
|
21Ch |
On |
Off |
Off |
|
|
238h |
Off |
On |
Off |
|
|
23Ch |
On |
On |
Off |
|
DRAM CONFIGURATION |
||
|
Memory Size |
Bank 0 |
|
|
» |
128KB |
(2) 64K x 9 |
|
|
2MB |
(2) 1M x 9 |