M 2 9 0 3 R A FUJITSU NO MORE PRODUCED Native| Translation ------+-----+-----+----- Form 3.5"/HH Cylinders 3150| | | Capacity form/unform 2100/ MB Heads 13| | | Seek time / track 10.0/ 2.0 ms Sector/track | | | Controller SCSI2 DI/WI/FAST Precompensation Cache/Buffer 512 KB Landing Zone Data transfer rate 4.700 MB/S int Bytes/Sector 512 10.000 MB/S ext SYNC Recording method RLL 8/9 operating | non-operating -------------+-------------- Supply voltage 5/12 V Temperature *C 5 50 | -40 60 Power: sleep W Humidity % 20 80 | 5 95 standby W Altitude km -0.300 3.000| -0.300 12.000 idle W Shock g 5 | 50 seek W Rotation RPM 5400 read/write W Acoustic dBA 43 spin-up W ECC Bit MTBF h 500000 Warranty Month Lift/Lock/Park YES Certificates ********************************************************************** L A Y O U T ********************************************************************** FUJITSU M2909R/2903R/2915R JUMPER SETTING +------------------------------++-------------------------+ | +--++++ CN6xxx |XXI | | +CN9 |XXN | +----------+ | + | |XXT | | | | + | |XXE | | | | + | CN7+-+ |XXR | | | CN25+ | | | |XXF | | | | + | +-+ |XXA | +----------+ +--+-++ |XXC | +--++-+ CN4+-+ |XXE | | +CN8 | | |XX | | + | +-+ |XX | +-+CN20 | + | | | +-+ CN24+ | | | | + | | | | + | |XX Power | +--+-++ |XX +--------------------------------++-----------------------+ ********************************************************************** J U M P E R S ********************************************************************** FUJITSU M2903RA/Q/M2909RA/Q/M2915RA/Q JUMPER SETTING Jumper Setting ============== * = Factory default Terminal Connector CN4 SCSI ID ------------------------------ +----------+-------------------------------+ | SCSI ID | Jumper Location | +2-4-6-8+ | | PINS | |* * * *| | | ID4 | ID2 | ID1 | ID0 | |* * * *|CN4 +----------+-------+-------+-------+-------+ +1-3-5-7+ | 0 | OPEN | OPEN | OPEN | OPEN | +----------+-------+-------+-------+-------+ | 1 | OPEN | OPEN | OPEN | CLOSED| +----------+-------+-------+-------+-------+ | 2 | OPEN | OPEN | CLOSED| OPEN | +----------+-------+-------+-------+-------+ | 3 | OPEN | OPEN | CLOSED| CLOSED| +----------+-------+-------+-------+-------+ | 4 | OPEN | CLOSED| OPEN | OPEN | +----------+-------+-------+-------+-------+ | 5 | OPEN | CLOSED| OPEN | CLOSED| +----------+-------+-------+-------+-------+ | 6 | OPEN | CLOSED| CLOSED| OPEN | +----------+-------+-------+-------+-------+ | 7 | OPEN | CLOSED| CLOSED| CLOSED| +----------+-------+-------+-------+-------+ | 8 | CLOSED| OPEN | OPEN | OPEN | +----------+-------+-------+-------+-------+ | 9 | CLOSED| OPEN | OPEN | CLOSED| +----------+-------+-------+-------+-------+ | 10 | CLOSED| OPEN | CLOSED| OPEN | +----------+-------+-------+-------+-------+ | 11 | CLOSED| OPEN | CLOSED| CLOSED| +----------+-------+-------+-------+-------+ | 12 | CLOSED| CLOSED| OPEN | OPEN | +----------+-------+-------+-------+-------+ | 13 | CLOSED|CLOSED | OPEN | CLOSED| +----------+-------+-------+-------+-------+ | 14 | CLOSED| CLOSED| CLOSED| OPEN | +----------+-------+-------+-------+-------+ | 15 | CLOSED| CLOSED| CLOSED| CLOSED| +----------+-------+-------+-------+-------+ Set the SCSI ID so that there are no duplications between SCSI devices on the SCSI bus. The priority of SCSI bus use in ARBITRATION phase is determined by SCSI ID as follows: 7>6>5>4>3>2>1>0>15>14>13>12>11>10>9>8 Terminal Connector CN6 ---------------------- +6-4-2+ |* * *| |* * *| CN6 +5-3-1+ D P A Spindle motor control A SHORT* Auto Start on power up OPEN Controlled by START/STOP UNIT command Set how to control the starting HDD spindle motor. This setting only determines the operation mode when the power supply is turned on or the microcode is downloaded. In both modes, stopping or restating the spindle motor can be controlled by specifying the START/STOP UNIT command. SCSI Bus Parity checking ------------------------ P SHORT* Enabled OPEN Disabled Offline Self-diagnostics ------------------------ D SHORT* Diagnostic Mode OPEN Normal Operation Setting terminals CN5-6 are used to set starting/stopping the HDD self-diagnostics. The offline self-diagnostics can test the normality of the HDD controller function and the basic read/write operation, the setting terminals must be open. Terminal Connector CN7 ---------------------- Spindle Sync I/O pulse. Master & Slave control determining whether to receive or transmit SPSYNC are set by MODE SELECT command. This terminal SY Pin 1 GROUND Pin 2 SPSYNC External Reset. This would normally be connected to a momentary switch which would short pin 3 to ground for the reset of the drive and SCSI bus. Normally used for debug purposes only. R SHORT* External reset signal when connected to ground OPEN No connection CN7 Pins 5-6 Write protection ----------------------------- WP SHORT Write operation is disabled OPEN* Write operation is enabled CN7 Pins7-8 Termination of SCSI bus (Single-Ended type, 8-bit) -------------------------------------------------------------- TM SHORT* Enable terminating resistor OPEN Disable terminating resistor Setting terminal CN7 7-8 set whether to use the terminating resistor circuit on the SCSI interface provided for the HDD. The setting terminals enable the terminating resistor circuit to be connected on the SCSI interface. Only the HDD of the single-ended type is provided with the terminating resistor circuit. CN7 Pins7-8 Termination of SCSI bus (Differential type, 16-bit) --------------------------------------------------------------- 7-8 SHORT* 16-bit SCSI mode setting OPEN 8-bit SCSI mode setting Set setting terminal CN7 7-8 enable or disable the 16-bit SCSI mode. When the 16-bit SCSI mode is enabled, all data bus (DB00 to DB15, DBP0 to DBP1) can be effective. When the Differential type 16-bit SCSI HDD is used as 8-bit SCSI device, this setting must be open. Terminal Connector CN20 External LED connector ---------------------------------------------- Pin 1 LED(V) Pin 2 -LED CN10 Single-Ended 16-bit ------------------------ +4-2+ |* *| |* *| CN10 +3-1+ Setting terminals CN10 1-2 and 3-4 set whether to use the terminating resistor circuit on the SCSI interface provided for the HDD. The setting terminals enable the terminating resistor circuit to be connected on the SCSI interface. CAUTION This setting is effective when the external operator panel (S6) is connected and pin A9 (TERM-ON) is open. +-------+-------+---------------------------------------------------+ |Pins | Pins |Connection of the terminating resistor on the SCSI | |1-2 | 3-4 |Interface | +-------+-------+---------------------------------------------------+ |OPEN | OPEN |Terminating resistor circuit is not connected | +-------+-------+---------------------------------------------------+ |CLOSED | CLOSED|Terminating resistor circuit is connected | +-------+-------+---------------------------------------------------+ CN10 Setting connecting of terminating resistor on SCSI interface ----------------------------------------------------------------- (Single-ended type 16-bit SCSI is used as 8-bit SCSI) +-------+-------+---------------------------------------------------+ |Pins | Pins |Connection of the terminating resistor on the SCSI | |1-2 | 3-4 |Interface | +-------+-------+---------------------------------------------------+ |OPEN | CLOSED|Terminating resistor circuit is not connected | +-------+-------+---------------------------------------------------+ |CLOSED | CLOSED|Terminating resistor circuit is connected | +-------+-------+---------------------------------------------------+ ********************************************************************** I N S T A L L ********************************************************************** FUJITSU M2903/M2909/M2915 JUMPER SETTING Notes On Installation ===================== Installation direction ---------------------- horizontally vertically +-----------------+ +--+ +--+ | | | +-----+ +-----+ | | | | | | | | | +-+-----------------+-+ | | | | | | +---------------------+ | | | | | | | | | | | | | | | | | | +---------------------+ | +-----+ +-----+ | +-+-----------------+-+ +--+ +--+ | | | | +-----------------+ The drive will operate in all axis (6 directions). Installation direction ---------------------- The drive may be installed in one of 6 orientations, that is on any of its facets. Inclination from vertical should be less than 5*. Mounting screws --------------- Either side or underside mounting may be used. Standard drive use M3 screws but some special models and US versions use 6/32 UNC. Screws should not protrude from the drive frame by more than 3mm or damage may occur. Mounting Screws: M3 x 5mm#6/32 UNC, M3 x 5mm#6/32 UNC Frame clearance --------------- There should be a gap of at least 2.5mm between the drive and the system mounting frame on all sides to provide for adequate air flow. Grounding --------- The M29xx series drives use Magneto-Resistive (MR) heads and therefore require special handling considerations. Users must ensure that the DE casing is NEVER shorted to the computer system's Frame or DC Ground. Recommended Parts For Connection -------------------------------- Part | Manufacturer | Part Number -----------------------------+---------------+----------------- SCSI Connector (closed end) | Fujitsu Ltd. | FCN-707B050-AU/B -----------------------------+---------------+----------------- SCSI Connector (through-end) | Fujitsu Ltd. | FCN-707B050-AU/O -----------------------------+---------------+----------------- Power Connector(housing) | | AMP 1-480424-0 -----------------------------+---------------+----------------- (contact for wire AWG 18 24) | | AMP 170121-4 -----------------------------+---------------+----------------- DC Grounding (faston) | | AMP 62187-1 -----------------------------+---------------+----------------- External LED (housing) | ELCO | 608283302815000 -----------------------------+---------------+----------------- (contact for wire AWG 24 30) | ELCO | 608283052330808 -----------------------------+---------------+----------------- ********************************************************************** F E A T U R E S ********************************************************************** NEVER NEVER PRODUCED!